TRansportation SOLUTIONS

SMARTON is uniquely positioned in the uninterruptible power supply ups for railway infrastructure. Many rail applications are critical loads that require uninterrupted power of suitable quality and cannot tolerate even the briefest lapse in power flow.

Modular, redundant true online UPS system can ensure the safe and continuous flow of rail traffic. Optimized investment in control and signaling systems maximizes the use of rail networks, and lowers the cost of new infrastructure and railway lines. UPS systems ensure rail networks deliver efficient, punctual, secure and reliable service, providing uptimes in the range of 99.9999 percent.

  • Online UPS for Railway Signaling
    Implementing a true online UPS system for railway signaling involves several considerations due to the critical nature of signaling in railway operations. Here’s a general outline of how such a online UPS system could be implemented:
  • Requirement Analysis
    Conduct a thorough analysis of the signaling system’s power requirements, including peak power demands, voltage stability requirements, and backup power duration needed during outages.
  • System Design
    Design a true online UPS system that meets the signaling system’s requirements. This UPS system should provide continuous power without any interruption or switchover time. It should also include features such as voltage regulation, surge protection, and isolation to ensure stable and clean power supply to the signaling equipment.
  • Redundancy
    Incorporate redundancy into the UPS system to enhance reliability. This may include redundant UPS modules, redundant batteries, and redundant power distribution paths to ensure uninterrupted power supply even in the event of component failures.
  • Battery Backup
    Select appropriate battery backup systems capable of providing the required power during outages. Consider factors such as battery capacity, recharge time, and expected battery life.
  • Monitoring and Control
    Implement a robust monitoring and control system to continuously monitor the UPS system’s status and performance. This system should provide real-time alerts and notifications in case of any issues or failures.
  • Environmental Considerations
    Ensure that the UPS system is designed to withstand the harsh environmental conditions typically found in railway settings, including temperature extremes, vibration, moisture, and dust.
×